fluids. The valves should be used on compressible fluids only, not incompressible fluids such as water or oil. / (GI) The Consolidated Series Electromatic Ball Valve is designed to provide automatic or manual overpressure protection for steam boiler systems, and can also be used to assist start-up and shut-down venting. relief valve styles, sizes, options and configurations for multiple industries, applications, environments, and media. From spring-actuated to pilot-operated, each pressure relief valve is configured to offer safer process flow control in harsh environments. Electronic Relief Valve (ERV) Page 6. GENERAL. This manual describes the procedures to be followed to ensure safe and successful installation, operation and maintenance of the metal-seated ball valve, actuator, electronic control, and sensing system that constitute the electronic relief valve (ERV), assuring a trouble free service life.
Type Electromatic Ball Valve. The Consolidated Series Electromatic Ball Valve (EBV) is designed to provide automatic or manual overpressure protection for steam boilers, and can also be used to assist start-up and shut-down venting. The EBV offers increased boiler efficiency. Power Actuated. Features: Consolidated Electromatic relief valves provide manual or automatic overpressure control by the plant operator. These electrically actuated safety devices are utilized on superheated and saturated steam applications at sub critical and supercritical pressures to psig. electromatic relief valve No. RV (RC) each is in-stalled. One additional relief valve of the'same type has been purchased as a spare valve. Photographs of the spare relief valve are shown in Figs. 1 and 2 The valve is a 2)" size. The valve is installed in the reactor coolant piping system No. 50 It is i designated as a Class A piping system.
electromatic relief valve No. RV (RC) each is in-stalled. One additional relief valve of the'same type has been purchased as a spare valve. Photographs of the spare relief valve are shown in Figs. 1 and 2 The valve is a 2)" size. The valve is installed in the reactor coolant piping system No. 50 It is i designated as a Class A piping system. Features: Consolidated Electromatic relief valves provide manual or automatic overpressure control by the plant operator. These electrically actuated safety devices are utilized on superheated and saturated steam applications at sub critical and supercritical pressures to psig. Type Electromatic™ Ball Valve. The Consolidated series EBV reduces start-up and shutdown time when used for venting steam in subcritical units. It increases plant efficiency by providing repeatable seat tightness. • Optimized ball and seat design to provide a consistent seat tightness. • New digital controller interfaces with modern distributed control systems or DCS.
0コメント